<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-24 01-29-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 4/5, 35 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
8 kHz 10 kHz 13578 0,1031
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -1,00 dBr -0,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 1:29, 24.05.2024
RT
"Jak to vidi... - Aktualni pocasi, supercely, ale take rady, j..."
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 10 kHz MIN: 8 kHz % above 77 kHz: 0,1031 Acquired: 2024/05/24 1:29:38 Total samples: 13578 Equivalent time: 0:11:18 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: -0,5 dBr MIN: -1,4 dBr AVE: -1,00 dBr % above 0,2 dBr: 0,0 Last value: -1,0 dBr (2024/05/24 1:29:37) 01:16 01:18 01:20 01:22 01:24 01:26 01:28 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality